EEGJev: A System One Decision Model and Benchmark for Multi-Task EEG Question Answering

Media reports Hugging Face Papers Source language: Chinese

Tohoku University introduces EEGJev, a one-pass EEG decision model, and EEGJev-Bench across 19 sources, achieving 99.70% attribute selection accuracy and faster latency…

Full text

\unnumbered

EEGJev: A System One Decision Model and Benchmark for Multi-Task EEG Question Answering

Dengzhe Hou Affiliation: Graduate School of Information Sciences, Tohoku University, Sendai, Japan Affiliation: Unprecedented-scale Data Analytics Center, Tohoku University, Sendai, Japan Kazunori D. Yamada Affiliation: Graduate School of Information Sciences, Tohoku University, Sendai, Japan Affiliation: Unprecedented-scale Data Analytics Center, Tohoku University, Sendai, Japan

Abstract

A single electroencephalographic (EEG) recording can support multiple decoding tasks. Fixed-label tests cannot show how EEG foundation models handle changing questions or options. We introduce EEGJev, a fast decision model that scores candidate answers in one pass. Our benchmark, EEGJev-Bench, covers six question types across 19 public EEG sources. We held the recording and options fixed while switching between questions about attributes paired during training, such as facial expression and the hand participants were asked to use. Across 13 test sources, EEGJev selected a label for the requested attribute with 99.70% accuracy (49.20% under uniform choice). Balanced accuracy for the specific answer was 62.04%. Its 95th-percentile response time was shorter than NeuroLM’s on matched validation questions answered individually. EEGJev lets users switch decoding targets by changing the question. With EEGJev-Bench, researchers can test whether new decoders follow the question more reliably, identify the correct answer more often, or both.

keywordsEEG, benchmark, question answering, refusal, foundation models

We introduce EEGJev, a question-guided EEG decision model (Figure 1).

Figure 1: EEGJev. CBraMod, fine-tuned on all sources in step 1 and then frozen, turns the window into C×LC\times L tokens, and per-source hidden layers add one spatial token. Frozen MPNet reads the question and the offered candidates, each candidate with a marker position. A two-layer bidirectional transformer reads all tokens together and scores each candidate at its marker, with a softmax over the offered candidates. A separately trained Act head decides whether to answer, and D3 is answered by a branch of the same head trained further on D3 questions. For T1 the head reads the tokens of two windows and for T2 those of up to eight ordered blocks of at most 4 s, each marked by an owner or block embedding. Direct attention from candidate tokens to EEG tokens is restricted to the candidate’s window in T1 and to blocks overlapping its half in T2.

Electroencephalographic (EEG) decoding tests which aspects of perception and action can be inferred from scalp recordings. An experimental trial can link a recording to several annotations, including the stimulus presented and the response that the participant was asked to make. For the same second of EEG in Figure 2, a decoder should answer “fearful” when asked about the facial expression and “left hand” when asked about the instructed response. Selecting a task-specific classifier fixes the prediction target in advance. A researcher who wants to predict a different attribute of the same trial must then select another classifier or output head. A decoder that accepts a question would let the researcher specify the target when analyzing the recording. Can one decoder follow a change in the requested attribute for the same recording, and how often does it choose the correct answer?

LaBraM 1 and CBraMod 2 reuse pretrained EEG encoders across tasks, usually with a separate head for each prediction target. NeuroLM 3 generates answers from instructions. LEAF 4 uses the instruction to score candidate labels, and METIS 5 scores the offered options. Evaluating such models with a different choice set for each question can make the target apparent from the options.

For example, choices that contain only expressions or only hand labels reveal which attribute is being asked about. Keeping the EEG and the ordered list of answer options fixed lets us test whether a change in the question changes the attribute of the selected answer. There is also a distinction between asking two questions and requiring two decisions. PhysioBench 6 asks multiple questions about one EEG window. For its paired seizure questions, identifying the seizure state also answers whether a seizure is present (released construction code). BrainBench 7 includes refusal cases without matched answerable controls. Pairing a refusal item with an answerable version tests whether a decoder also responds when a correct option is available.

A shared CBraMod encoder represents the signal, and a frozen MPNet encoder 8 represents the question and candidate answers. Jev and Laya are System One models that return decisions directly 9. Following Laya’s design 10, EEGJev’s decision head reads the EEG and text representations together and scores every offered answer in one pass. Changing the question can thus query a different attribute through the same scoring interface. A separately trained head decides whether to answer, and a branch of the decision head receives further training for ordered categories such as age groups. For two-window comparisons and long-window questions, the decision head uses information about which window or time block the signal tokens come from. The same head thus scores window and time choices as well as attribute labels.

We also introduce EEGJev-Bench, which covers six question types across 19 public EEG sources. To build it, we checked the public releases against their original datasets and applied a common processing pipeline to obtain EEG windows. Within each scored source, different participants provide the training and test windows. To assess two predictions from one window, we pair questions whose answers do not determine one another in that source’s training recordings. The pair score requires a correct answer to each question, measuring whether the model can answer both on the same trial. To test refusal, we remove the correct option from one version and a distractor from the other. The two versions share the EEG and the question and offer the same number of choices, with the correct option available in one version. The other tasks ask about a single attribute or an ordered category, compare two windows, or locate an event within a longer window.

Figure 2: EEGJev-Bench. a, We checked the public EEG releases against their original datasets and corrected discrepancies when building the benchmark. Within each scored source, training and test windows come from different participants. Each question pairs one or two EEG windows with a prompt and answer choices. D1–D4 and T1 use windows of 1, 2 or 4 s. b, D1 asks about one attribute. D2 asks two questions about the same window, chosen so that knowing one answer does not reveal the other. D3 asks the model to select an ordered category, such as an age group. D4 tests refusal by removing the correct option. A matched, answerable version removes one incorrect option. D1h repeats each D1 test question using two phrasings absent from training. c, T1 asks which of two windows shows a given label. T2 asks whether an event occurs in the first or second half of an 8, 16 or 30 s window. The D3 example uses the Dortmund age bins. The highlighted bin illustrates one possible answer. The other five examples come from the asym validation set.

For each task type, the aggregate gives each scored source equal weight, regardless of how many windows it contains.

We changed the question while keeping the EEG window and answer options fixed. For attribute pairs seen during training, EEGJev almost always chose a label for the requested attribute. Choosing the correct answer was harder. On the same binary validation questions answered individually, its 95th-percentile response time was shorter than NeuroLM-B’s on both a single CPU core and a GPU. EEGJev lets users choose what a single decoder should identify in a recording by changing the question. EEGJev-Bench gives researchers a common test of whether a new decoder follows the question more reliably, chooses the correct answer more often, or both.

1 Results

1.1 Question-guided selection of familiar attributes

We first held both the EEG window and the ordered list of options fixed and changed only which attribute the question asked about. Each list contained four to ten options from two disjoint label sets. All tested attribute pairs appeared in training. Across 13 sources, EEGJev chose a label for the requested attribute with 99.70% test accuracy (49.20% for uniform choice). Balanced accuracy for the specific answer was 62.04% (Figure 3a). When both questions had to be answered correctly, the source-balanced score was 44.37%.

We also tested how EEGJev responds when the question points to the wrong attribute. On D1, we replaced the question with one about another task from the same source, keeping the EEG window, candidates and reference answer fixed (Figure 3b). Test balanced accuracy falls by 12.6 percentage points (95% interval for the change, −14.1-14.1 to −11.1-11.1). An empty question lowers the score by 1.3 points, an untrained task code by 1.9 and the two held-out phrasings by 2.9 and 1.3. Scores are stable under candidate rotation. With letter codes in place of candidate names, test balanced accuracy is 43.5% with or without the mapping in the question, close to the controls without matching EEG. Training used the mapped format for 10% of D1 and D2 questions. Validation shows the same pattern. The question guides attribute selection, and candidate names help EEGJev identify the specific answer.

1.2 Answer accuracy on familiar tasks

On the D1 test tasks, balanced accuracy averaged across sources was 63.8% for EEGJev and 64.5% for task-specific EEGNet (Table 1). The paired difference was −0.69-0.69 percentage points (95% interval −1.77-1.77 to +0.26+0.26 from resampling the 217 test participants within sources). On validation, the corresponding difference was −2.0-2.0 percentage points (95% interval −3.2-3.2 to −0.8-0.8 from resampling tasks within sources). The ordinary classifier on the same encoder reached 64.2% on test, 0.3 points above EEGJev (−0.5-0.5 to +1.1+1.1). LaBraM reached 64.3% on the 96 tasks it covered and was 0.5 points below EEGJev on those tasks (−1.5-1.5 to +0.5+0.5). After temperature scaling, EEGJev’s D1 calibration error was 2.0% (test) and 2.4% (validation). LaBraM had the highest test error (9.7%).

Figure 3: Question following, text controls and transfer to held-out tasks.a, Two questions about familiar attributes share an EEG window and an ordered list of options. The left column counts a label as correct when it belongs to the requested attribute. EEGJev scores average three training seeds for each of 13 test sources (380,570 eligible questions per seed). The last row weights sources equally.b, Changes are relative to scores with the original D1 questions and options. Whiskers show paired 95% intervals from resampling tasks within sources. Letter codes replace the candidate text. The test set covers 109 tasks from 17 sources.c,d, Bars show means across three training seeds.

Figure 4 compares the six question types. NeuroLM was instruction-tuned on benchmark D1–D3 questions. On the 99 D1 tasks it covers, NeuroLM scores 58.6%, 5.4 points below EEGJev (−6.6-6.6 to −4.3-4.3). With released weights, METIS and LEAF score 43.5% to 45.0%, close to controls without EEG (43.5% to 43.8%).

Figure 4: Model comparisons across EEGJev-Bench. Each pair of bars compares EEGJev with the named baseline on the test tasks that both cover. The Tasks column gives this count. Scores weight sources equally. d, The upper rows compare EEGJev’s trained refusal head with confidence thresholds. The lower rows apply the full-label check to both models. e,f, Fixed rules combine D1 outputs. The lower rows in f use time-ordered readouts trained on the same T2 labels as EEGJev.

For D1h, we asked familiar D1 questions using wording held out from training. With a shared encoder, EEGJev’s test balanced accuracy falls from 63.8% to 61.7% (59.7% to 62.9% across seeds). With a separate encoder for each source, it falls from 64.1% to 59.8% (53.7% to 63.4% across seeds). NeuroLM loses 3.1 points. The ordinary classifier does not read the question and is unchanged (Supplementary Note Supplementary Note 8. Held-out phrasings, Supplementary Table 3).

Table 1: D1 source-balanced mean balanced accuracy (%), seed means, each model over the tasks it covers. Differences to EEGNet are paired over the Tasks column on common rows, with 95% intervals from a bootstrap over tasks within sources. LaBraM has no models for chbmit, hbn and sleep, NeuroLM no input for hbn and sleep, and LEAF no predictions for chbmit, deprest, hbn, mom and sleep. The averaged row uses the rule described in “1.4 Inference rules for known tasks and ordered-bin scores”. Validation is used for model selection where applicable. Shading shows BA on all 109 tasks. Bold marks the highest BA within each split.

Test Validation

Model Tasks BA minus EEGNet BA minus EEGNet

Models trained on EEGJev-Bench

EEGNet, one model per task 109 64.5 66.4

EEGJev 109 63.8 −0.7-0.7 (−2.0-2.0, +0.6+0.6) 64.4 −2.0-2.0 (−3.2-3.2, −0.8-0.8)

Ordinary classifier 109 64.2 −0.4-0.4 (−1.5-1.5, +0.7+0.7) 64.9 −1.5-1.5 (−2.5-2.5, −0.5-0.5)

EEGJev and ordinary, averaged 109 65.2 +0.7+0.7 (−0.5-0.5, +1.9+1.9) 65.9 −0.5-0.5 (−1.5-1.5, +0.6+0.6)

LaBraM, one model per task 96 64.3 −1.4-1.4 (−2.6-2.6, −0.1-0.1) 65.7 −2.6-2.6 (−3.7-3.7, −1.6-1.6)

NeuroLM, instruction-tuned 99 58.6 −6.5-6.5 (−8.2-8.2, −5.0-5.0) 58.9 −8.8-8.8 (−10.5-10.5, −7.2-7.2)

Models with fixed weights

METIS, fixed weights 109 43.5 −21.0-21.0 (−23.3-23.3, −18.6-18.6) 43.1 −23.3-23.3 (−25.3-25.3, −21.2-21.2)

LEAF, level 0 87 44.8 −18.7-18.7 (−21.2-21.2, −16.2-16.2) 44.8 −21.4-21.4 (−23.6-23.6, −19.1-19.1)

LEAF, level 1 87 45.0 −18.6-18.6 (−21.1-21.1, −16.2-16.2) 45.3 −20.9-20.9 (−23.2-23.2, −18.5-18.5)

LEAF, level 2 87 44.8 −18.7-18.7 (−21.2-21.2, −16.3-16.3) 45.5 −20.7-20.7 (−23.1-23.1, −18.4-18.4)

Per-source encoders

EEGJev, per-source encoders 109 64.1 −0.5-0.5 (−1.5-1.5, +0.6+0.6) 65.3 −1.2-1.2 (−2.1-2.1, −0.2-0.2)

Ordinary, per-source encoders 109 64.7 +0.2+0.2 (−0.7-0.7, +1.2+1.2) 66.9 +0.5+0.5 (−0.8-0.8, +1.7+1.7)

For D2, the joint score gives equal weight to observed answer combinations and requires both questions about the same window to be answered correctly (Figure 2b). On test, EEGJev, the ordinary classifier and task-specific EEGNet scored 39.3%, 41.0% and 44.2%, respectively (Figure 5a). Scoring the questions individually gives balanced accuracies of 61.1%, 62.2% and 63.0% on test and 62.9%, 64.3% and 65.3% on validation, in the same model order. On the 59 matched tasks, the per-question difference between EEGJev and EEGNet is −2.0-2.0 percentage points on test (95% interval −3.7-3.7 to −0.2-0.2, Figure 5b) and −2.4-2.4 on validation (−4.0-4.0 to −0.9-0.9). The corresponding test difference between the ordinary classifier and EEGNet is −0.8-0.8 points (−2.2-2.2 to +0.6+0.6).

Figure 5: Paired questions, ordered bins and refusal. a, Dark and light bars show balanced accuracy per question and joint accuracy, respectively. The joint score balances across observed answer combinations. Each model is scored on the tasks it covers. Ordinary denotes the ordinary classification head, and fused denotes its equal-weight combination with EEGJev. PS denotes a per-source model. b, Each open circle is one of 59 matched tasks. Bars show source means and the equally weighted mean over ten sources. c, Colour bars and values show the balanced accuracy of the shared EEGJev D3 branch on 22 tasks by window length. Dashes mark unavailable tasks. d, Mean absolute bin error for models covering all 22 tasks. e, The score averages the rate of refusing when no option fits and the rate of answering when a correct option is present. The full-label check also scores every known class. f, Matched differences between the shared refusal head and the listed confidence rules. The right column gives each comparison’s task count. Whiskers in b,f give paired 95% intervals from 10,000 resamples of tasks within sources, conditional on the evaluated participants. The scores are from the test split.

1.3 Refusal when the correct option is absent

EEGJev’s D4-trained refusal head (Act) scored 59.2% on test and 58.6% on validation (Figure 5e). On matched test tasks it scores 4.8 points above the confidence threshold on its own predictions (+4.2+4.2 to +5.4+5.4) and 6.2 above EEGNet’s (+5.1+5.1 to +7.3+7.3, Figure 5f). Confidence rules for NeuroLM, METIS and LEAF score close to 50%, as does a rule that makes the same decision throughout each group. On their respective matched tasks, Act scores 7.8 points above NeuroLM’s rule (+6.0+6.0 to +9.6+9.6) and 9.2 above METIS’s (+7.7+7.7 to +10.8+10.8). NeuroLM’s threshold was calibrated on D4 validation after training on D1–D3.

For tasks seen in training, the full-label check scores all answers of the task and refuses when the best one is not offered. On the same 31 D4 test tasks, this rule gives 65.4% for EEGJev and 66.7% for EEGNet (Supplementary Note Supplementary Note 11. Inference rules for known tasks).

1.4 Inference rules for known tasks and ordered-bin scores

For tasks seen in training, averaging the log-probabilities of EEGJev and the ordinary classifier with equal weights gives 65.2% on test D1 and 63.2% on test D2. This is 1.4 points above EEGJev on D1 (+1.0+1.0 to +1.8+1.8) and 2.1 points on D2 (+1.4+1.4 to +2.9+2.9), and it is not distinguishable from EEGNet on D1 (+0.7+0.7, −0.5-0.5 to +1.9+1.9) or on D2 (+0.2+0.2, −1.3-1.3 to +1.6+1.6). Averaging and the full-label check were fixed before v1.3 test evaluation and applied to the saved test outputs without additional fitting (Supplementary Note Supplementary Note 11. Inference rules for known tasks). Both apply only to tasks with known training labels.

Figure 5c,d shows D3 accuracy by task and mean error in bins. The D3 branch of EEGJev reaches 41.5% on test and EEGNet 42.5%, a paired difference of −1.0-1.0 points (−2.8-2.8 to +0.8+0.8). The bin heads of the ordinary classifier reach 42.4%. On the 14 D3 tasks covered by LaBraM, the D3 branch scores 34.0% and LaBraM 39.7% (Figure 4c). The mean bin distance is 0.80 for the D3 branch, 0.83 for the ordinary bin heads and 0.75 for EEGNet. On validation the branch is at 41.3% and EEGNet at 42.7%. Without the branch, the decision head answers D3 at 35.3% on test, 7.2 points below EEGNet (Supplementary Note Supplementary Note 12. D3 without the further-trained branch), so the binned questions are matched only with the further-trained branch.

1.5 Questions over two windows and long windows

Figure 6 compares direct T1 and T2 answers with fixed rules that combine D1 outputs (see “3.3.1 Baselines”).

On T1, EEGJev reaches 77.7% on test and on validation. Composing the answer from its own D1 outputs gives 78.1%, so the native answer is not better than the composition here. The composition from EEGNet reaches 80.8% and is 3.1 points above EEGJev (interval 1.8 to 4.4), and the ordinary classifier is 1.1 points above it (0.3 to 2.0). LaBraM (77.5%) is not distinguishable from EEGJev on the 80 tasks it covers, and NeuroLM is 7.1 points lower.

With the same early-versus-late training labels, EEGJev read the long window directly and scored 68.31% on 15 matched T2 test tasks from seven sources (Figure 6c). Trained readouts of the frozen one-second EEGNet and shared ordinary classifier both scored 58.62% using time-ordered class probabilities. Using mean probabilities over the window, they scored 53.21% and 52.63%, respectively. EEGJev led the ordered EEGNet readout by 9.69 points. The 95% interval was +7.43+7.43 to +12.22+12.22 points when resampling the 37 test participants within the seven sources and −1.55-1.55 to +24.16+24.16 points when also resampling sources.

We also compared EEGJev with fixed rules that combined consecutive one-second D1 predictions without fitting to T2 labels (Figure 6b,d,f). EEGJev reaches 69.8% on test and 67.1% on validation. Every composition is lower. The composition from EEGJev’s own D1 outputs reaches 61.8%, 6.5 points below the native answer (−9.2-9.2 to −3.7-3.7), the ordinary classifier 61.2% (−7.1-7.1, −9.1-9.1 to −5.2-5.2) and EEGNet 61.8% (−6.5-6.5, −9.4-9.4 to −3.8-3.8). The best composition, from the per-source ordinary classifier, is 4.9 points lower (−7.7-7.7 to −2.3-2.3). On validation every composition is lower as well, with EEGNet 4.3 points below EEGJev (−7.5-7.5 to −1.0-1.0). These comparisons use fixed rules for 15 of the 17 T2 tasks.

Figure 6: Temporal decisions across questions and sources. a,b, Bars give source-balanced accuracy on matched T1 and T2 tasks, respectively. Each dot shows the difference between EEGJev and the EEGNet rule on one task. EEGJev trained on temporal labels. The fixed rules compare D1 scores between windows for T1 and combine successive one-second D1 predictions for T2. c, EEGJev and both readouts trained on the same T2 labels. The readouts use time-ordered one-second class probabilities. Bars show paired source-balanced differences averaged across three seeds on 15 test tasks from seven sources and 37 participants. Whiskers give 95% intervals from 10,000 paired resamples of participants within fixed sources, or of sources and participants. d, Signed differences between EEGJev and the fixed EEGNet rule by source and duration. Dashes mark unavailable comparisons. PHOTO has direct scores for two durations. e,f, Paired differences between shared EEGJev and other models on T1 and T2, respectively. Whiskers give 95% intervals from 10,000 paired resamples of tasks within sources. Counts give the number of matched tasks in each comparison. The comparisons use fixed compositions except for the per-source direct head, which also trained on temporal labels.

1.6 Shared and per-source encoders

Training one encoder per source changes little. On test D1, EEGJev with per-source encoders is 0.2 points above the shared EEGJev (−0.6-0.6 to +1.0+1.0) and the per-source ordinary classifier 0.9 points above it (0.0 to +1.8+1.8). The per-source EEGJev is higher on D4 (60.5%) and lower on T2 (67.5%), and it loses more under the held-out phrasings. Supplementary Note Supplementary Note 7. Shared and per-source encoders gives the other comparisons.

1.7 Held-out tasks

A question-reading model can in principle answer a question it was not trained on, which a classifier without an output layer for it cannot. We removed one task at a time from all training, including step 1 of the encoder, its D1 rows, the D2 rows paired with it, its D3 and D4 rows, its T1 pairs and its classifier layer. We then asked the retrained model the task’s validation questions, which no part of the new model had used. Eye state of vrnf is a concept that other sources also ask about. Face gender of asym appears in no other source (several sources ask the gender of the participant, which is a different attribute).

Figure 3c,d shows the two held-out tasks. Supplementary Table Supplementary Note 14. Additional results and source data gives the individual training-seed scores. With vrnf eye state removed, EEGJev answers it at 78.9% balanced accuracy (seeds 76.7 to 80.8%, AUROC 0.86), against 48.6% with shuffled EEG and 83.1% for the model trained on the task. The per-source EEGJev reaches 81.2% (75.8 to 85.0%) against 87.2% in training. Eye state learned from other sources thus carries over to a source whose eye-state questions were never seen. Face gender does not transfer. EEGJev reaches 51.7% (46.5 to 60.3%, AUROC 0.53) and the per-source EEGJev 47.9%, at the level of shuffled EEG (49.7 and 50.1%), while the models trained on the task reach 82.1 and 82.5%. One seed of EEGJev is at 60.3% and the other two are below 50%. The evaluation is small (240 questions from five validation persons for vrnf, 3,909 from 14 persons for asym), and the ordinary classifier, EEGNet and LaBraM are not compared here because they have no output for a task removed from training.

1.8 Datasets no model has seen

On left-or-right-hand motor imagery in two datasets that no model had been trained or evaluated on, Weibo2014 11 with 10 persons and Dreyer2023A 12 with 60, EEGJev stays at chance (49.6% to 52.4%). The ordinary classifier (53.1% to 58.1%) is above it in all six conditions, by 2.2 to 7.0 points with intervals that exclude zero. Supplementary Note Supplementary Note 9. Datasets no model has seen describes the setup and few-shot calibration.

1.9 Response time for individual questions

EEGJev and NeuroLM-B answered the same 192 binary D1 validation questions (Exo walking transitions and LEMON eye state) one at a time, with checkpoints from three training seeds and 576 timed calls per model per platform. On one CPU core, the 95th-percentile response times were 394.97 ms for EEGJev and 3,677.34 ms for NeuroLM-B. On one GPU they were 9.60 and 24.99 ms, respectively. On each platform, EEGJev returned an offered option in all 576 calls and NeuroLM-B in 554. Timing started with preprocessed EEG in host memory, included text processing and answer return, and counted unparseable responses as infinite time to an offered option (Supplementary Note Supplementary Note 6. Compute and parameters).

2 Discussion

EEGJev-Bench measures two decisions separately. Does the answer match the requested attribute, and is its value correct? On attribute pairs seen in training, EEGJev selected the requested attribute with 98.0% to 100% accuracy across 13 test sources. Balanced accuracy for the specific answer ranged from 40.2% to 85.0% (Figure 3a). Task-specific EEGNet achieved higher joint accuracy on paired questions, and EEGJev’s refusal head outperformed EEGNet’s confidence rule. EEGJev scored the offered answers in one pass and had a shorter 95th-percentile response time than NeuroLM-B on the same 192 validation questions answered individually, on both a single CPU core and a GPU.

Golan et al. 13 used paired sentences to reveal failures that aggregate language-model scores could miss. Gu et al. 14 evaluated candidate selection in cardiac question answering, and EEGJev-Bench holds the EEG and answer choices fixed to test whether a decoder follows a change in the requested attribute.

Most sources taken from UniEQA have one to three test participants. Bootstrap intervals over tasks condition on these participants. Validation is used for model selection or calibration, and the D1 gap between EEGJev and EEGNet is larger on validation than on test. The long-window result rests on 17 tasks from 8 sources, and the event times of T2 are instruction, cue or scoring times. The refusal head scores 59.2%, 9.2 percentage points above the 50% baseline for a rule that ignores the EEG. Letter codes in place of the candidate names bring EEGJev down to the level of the controls without EEG, so it depends on the wording of the candidates. The held-out task results cover one concept seen in other sources and one attribute that no other source asks, and they show that transfer is possible, not how often it occurs. The motor-imagery transfer fills missing electrodes by interpolation, and the training data contain only two persons who imagine left and right hand movements. The decision-head stage of EEGJev trains 806.8 million parameters. Baselines use the benchmark’s splits and preprocessing. The fixed T1 and T2 rules combine D1 outputs. The supervised T2 readouts use the same T2 labels as EEGJev (Figure 6). METIS and LEAF use released weights. Comparisons with them involve differences in model design and training conditions.

EEGJev lets users specify what to decode from an EEG recording through a question and returns a probability for each offered answer in one pass. EEGJev-Bench holds the recording fixed while varying the question or the availability of the correct option, so researchers can assess question following, answer accuracy and refusal separately.

3 Methods

3.1 EEGJev-Bench

EEGJev-Bench asks multiple-choice questions about attributes such as the stimulus shown, the sleep stage or the participant’s diagnosis. All results use data version v1.3.

3.1.1 Sources and windows

We use recordings from the original releases of all 19 sources (Figure 2, Supplementary Note Supplementary Note 1. Sources and windows, Supplementary Table 1). For 12 sources from Unified_EQA, the public EEG question-answering release in UniEQA 15, we locate each of its segments in the original recording. The seven added sources are COG-BCI 16, HBN-EEG 17; 18, a verbal working memory dataset 19, the Dortmund Vital Study 20, ERP CORE 21, MPI-LEMON 22 and a resting-state depression dataset 23. Seventeen sources have scored tasks. The bciciv and is sources have three training persons each and no test persons in this version, so they serve as training material only.

Short windows last 1, 2 or 4 s. An event label gives one window from the event, and a state or person label gives at most eight non-overlapping windows per segment. Long windows of 8, 16 or 30 s are cut around an event for the T2 questions.

All recordings come from public datasets, and no new data were recorded for this study. For 15 of the 19 sources, the original publications or dataset pages state an ethics approval and the consent of the participants. Those of BCI Competition IV, CHB-MIT and Sleep-EDF state neither, and those of the depression dataset state consent without naming a review board.

3.1.2 Question types

D1 asks one attribute of one window. Its options are all train values of that attribute for the same source and window length, so they depend on the cell (source, attribute, window length) and not on the window. Each attribute has three phrasings, and a D1 row uses one of them. Each attribute also has two phrasings that occur in no training text, and every D1 test row is repeated with both of them (D1h).

D2 asks two attributes of the same window, each in all three phrasings. The pair is chosen so that neither attribute determines the other over the train segments of the source. D2 is scored per attribute, and a joint score counts a window as correct only when both attributes are answered correctly.

D3 asks the model to choose among ordered categories. The questions cover MMSE by clinical cut points (≥24\geq 24, 18–23, <18<18), age in the Dortmund, HBN and LEMON sources, sleep stage by level (Wake, N1, N2, N3), n-back load, the level of the MATB task and the foreground contrast in HBN. During benchmark construction, we merged two LEMON age bins (55–65 and 65–70 years) after the test label counts showed that the younger bin was empty (Supplementary Note Supplementary Note 2. Data quality rules). D3 is scored by balanced accuracy and by the mean absolute distance between the chosen and the true bin.

D4 tests refusal. For each D1 question with at least three options, D4 adds a refusal row, in which the correct option is removed, and a control row, in which one wrong option is removed and the correct answer remains. Both rows have one option fewer than the D1 question, so the number of options does not reveal the correct decision.

T1 shows two windows of the same person and of the same length and asks which of them carries a given label of a D1 task. Each pair gives four linked views, with the two windows in either order and each of the two labels asked. A window enters at most one pair of a task. T2 asks whether an event lies in the first or the second half of a long window. The event is placed near one quarter or three quarters of the window, with a jitter of one sixteenth of its length, and the two placements of an event form one linked group. The events are changes of eye state, seizure onsets, sleep stage changes, cued transitions, changes of flicker frequency and targets in a stimulus stream. Their labels are instruction, cue or scoring times, not measured neural onsets.

The train and validation persons have 940,604 short windows and 6,728,339 D1 to D4 questions. The test persons have 117,571 short windows and 878,827 questions, and D1h adds 488,786 rows. The scored T1 tasks have 557,933 train pairs, 94,924 validation pairs and 80,748 test pairs, and the scored T2 tasks have 64,465, 12,315 and 3,368 event groups.

3.1.3 Splits

In the 17 scored sources, participants belong to only one split. For the seven added sources, 15% of the persons form the test split and 15% of the rest the validation split, drawn with fixed seeds. For the sources from UniEQA, test and validation persons were drawn with fixed seeds in the numbers of the earlier data version, so most of these sources have few test persons (ten for dementia and photo, three for asym and sleep, two for chbmit, mom, surprise and vrnf, one for exo and gal). Photo and dementia record the same participants and are split jointly. The added sources have between 4 test persons (cogbci) and 91 (dortmund). Results are therefore reported per task and with the number of test persons in mind.

3.1.4 Data quality rules

In a study of six EEG datasets, changing preprocessing alone altered up to 42% of trial-level predictions 24. We use one signal pipeline to construct the benchmark windows. We read each recording from its original file using a fixed channel list. For ERP CORE, we first subtract the mean across the 30 scalp channels at each time point. We apply a notch filter at the mains frequency where a peak is present, resample the whole recording to 200 Hz and standardize each channel within each window. We exclude windows that start in the first 2 s, end in the last 0.5 s, lie within 0.1 s of a discontinuity marker or contain flat or dead channels. We correct labels against the original data, for example by restoring the official bciciv motor imagery labels and cutting each gal window from its own lift (Supplementary Note Supplementary Note 2. Data quality rules).

3.1.5 Evaluation protocol

Each row is scored with its own options in the given order. A task is a cell of one question type. The main metric of D1, D1h, D2 and D3 is balanced accuracy over answer labels, computed within each task. A task is scored only if every offered answer has at least 10 windows on validation and on test, and this task list was fixed on 15 November 2026 from the label counts alone, before any model was trained on this data version. It has 109 D1 tasks in 17 sources, 59 D2 tasks in 10 sources, 22 D3 tasks in 6 sources and 31 D4 tasks in 11 sources. Scores are averaged with equal weight for every source and equal weight for the tasks within a source (the source-balanced mean), so that a source with many tasks does not dominate. D3 also reports the mean absolute bin distance. The D2 joint score averages the nine combinations of phrasings of a window and is balanced over the combinations of the two answers.

In the fixed-option experiment, we count a question pair as correct only when both answers are correct and average the scores within each pairing condition, across conditions within each source and then across sources.

D4 is scored by a group-balanced criterion. A group holds the D4 rows that share source, attribute, window length and the unordered set of offered labels. Within a group, the criterion is the mean of the refusal recall on refusal rows and the answer rate on control rows, and a task’s score is the mean over its groups that contain both kinds of rows. A rule that does not look at the EEG cannot exploit which label is missing, since every decision that is constant within a group scores exactly 0.5. Every model can refuse by thresholding its calibrated maximum option probability. Per model, one temperature is fitted on validation D1 by negative log-likelihood and one threshold, shared across sources, is chosen on validation D4. Models with their own refusal output are also scored with it. Calibration is reported as the expected calibration error over 15 bins (ECE) of the D1 answers after temperature scaling.

T1 and T2 are scored by accuracy. The linked views of a pair or an event group are averaged first, then persons, tasks and sources, so that the four views of a pair do not count as four samples. A T1 or T2 task is scored when validation and test each have at least ten pairs or event groups, which leaves 93 T1 tasks in 16 sources and 17 T2 tasks in 8 sources. Chance is 50% for both.

3.1.6 Controls without EEG

Three controls receive no information from the EEG of the window being asked about (an answer prior, a text-only Laya checkpoint 10 and shuffled EEG). On D1 they reach 43.5% to 43.8% on validation and test, the level of the answer prior (Supplementary Note Supplementary Note 3. Controls without EEG, Supplementary Table 2).

3.2 EEGJev

EEGJev answers a multiple-choice question about EEG. It receives one window, or two windows for T1, the question text and the offered candidates. It returns one score per candidate and, from a separate output, whether it should refuse. The candidate set can change at run time, and nothing is generated or parsed (Figure 1).

EEG encoder.

The encoder is CBraMod 2 with the official pretrained weights. It reads each source’s native channels at 200 Hz in patches of one second, so a window of CC channels and LL seconds gives C×LC\times L tokens of width 200. In a first step, one encoder is fine-tuned on the D1 labels of all 19 sources together. Each source and window length has its own hidden layers, namely the two-layer head that CBraMod places on the flattened tokens (200​C​L200CL to 800 to 200 units, with ELU and dropout 0.1), and each cell has its own linear output layer. The encoder is then frozen. The same step-1 model with its per-cell output layers is the ordinary classifier described in “3.3.1 Baselines”.

Decision head.

The decision head is a small bidirectional transformer that reads one sequence per question. The sequence holds the window’s C×LC\times L CBraMod tokens, one spatial token, and the text tokens of the question and of each candidate. Each CBraMod token is projected to width 256 and receives a channel and a patch embedding. The spatial token summarizes the whole window. New hidden layers of the same shape as the step-1 heads, one set per source and window length, map the flattened CBraMod tokens to 200 units, and a linear layer and a learned embedding turn the result into one more token. CBraMod has no vocabulary, so the text is read by a frozen MPNet encoder (all-mpnet-base-v2 8), whose 768-dimensional token outputs are projected to width 256. Segment and question-type embeddings mark which part of the sequence a position belongs to, and each candidate has a marker position. The head has two pre-norm layers with four attention heads, a feed-forward width of 1,024 and dropout 0.1. Every position attends to every other position, so each candidate is scored in the context of the others. A two-layer scorer reads each marker and returns the candidate’s logit, and a softmax over the offered candidates gives the answer probabilities. This joint scoring of candidates at markers follows the typed decision model Laya 10. EEGJev uses none of Laya’s weights.

Two windows and long windows.

The same head answers T1 and T2. For T1, the tokens of both windows enter the sequence, and a learned embedding marks each token as belonging to window A or window B. The two candidates name the windows, and the tokens of a candidate attend to the EEG tokens of its own window only. For T2, the long window is cut into consecutive blocks of at most 4 s (1 s for erpcore, which has hidden layers for 1 s only), the frozen encoder reads each block separately with the hidden layers of its source and length, and a learned embedding gives the position of each block. The tokens of the candidate for the first half attend to the EEG tokens of the blocks

Sources

← Back to Daily AI Report